25
Shield to Earth Ground
on Supply End Only
Braided
Shield
Ferrite
Beads
Cable Length
50 Feet or greater
Phase A
Phase A
Phase B
Phase B
Phase A
Phase A
*L 0.5 MH
* 0.5 MH is a typical starting point for the
Common Mode Line Filters. By increasing
or decreasing the value of L you can set the
drain current to a minimum to meet your requirements.
Phase B
Phase B
Common Mode
Line Filters (2x)
Two Shielded/Twisted Pairs
(Wire Size from
IMS Driver to Motor Cable AWG Table)
Example B - Cabling 50 Feet or Greater,
IMS Driver to Motor